Operating at 2013 nm and delivering up to 3,700 W peak power, Thulio empowers urologists to confidently treat stones, BPH, and soft tissue applications with one versatile system that excels across all major endourological applications.
Stone
Fragmentation
Stone
Dusting
Stone
Retropulsion
Tissue
Enucleation
Tissue
Coagulation
All STRENGTH IN ONE LASER
Dornier Thulio – pulsed Tm:YAG
Highly efficient
in stone ablation1
Excellent
fine dusting comparable to TFL2
Low
retropulsion compared to Ho:YAG3
Highly efficient
smooth plane development4
Excellent
Often the best coagulation profile5
Ho:YAG
TFL
Ho:YAG
Strong
Ideal for very hard stones6
Inferior
to pulsed Tm:YAG7
High
compared to pulsed Tm:YAG7
Highly efficient
most mature laser technology4
OK5
Ho:YAG
TFL
Thulium Fiber (TFL)
Less efficient
in dense stone compositions8
Excellent
Produces fine dust particles9
Minimal9
Expanding
clinical evidence base10
Very good
hemostatic performance11
Dornier Thulio® combines effective lithriopsy, precise tissue performance, and broad clinical versatility on a single pulsed Tm:YAG platform —supported by a rapidly expanding body of prospective, comparative, multicenter, and systematic-review evidence.
Kidney Stones
Kidney Stones
High stone-free rates across procedures
(flex. URS, ECIRS & PCNL)12 reproducible results across different clinical settings.13
Effective dusting across stone compositions providing flexibility for everyday stone treatments.14
55% reduced retropulsion for enhanced control3
Supporting procedural efficiency3
16% shorter lasing time using FANS
Compared to TFL15
Proven performance for large and complex stones.13
BPH
BPH
96.1% patient satisfaction post-EEP16
Strong hemostatic control
Clinical reviews consistently report excellent coagulation characteristics, helping surgeons maintain visualization and procedural flow throughout treatment.17
Pulsed ThuLEP with Thulio delivers proven results over HoLEP16
UTUC
UTUC
80% tumor-free rate
Ablation performance on par with TFL outshining Ho:YAG18
REFERENCES:
Witness the infinite versatility of Thulio®, our 100W pulsed Thulium:YAG laser, in action. Trusted by clinicians worldwide and backed by a proven track record, Thulio® offers exceptional performance and reliable care, empowering you to provide the quality treatment your patients deserve.
Filter
Thulio offers a wide range of application modes, adapting to your needs and enabling smoother procedures.
Dusting mode
Fragmenting mode
Captive Fragmenting mode
Enucleation mode
Soft Tissue mode
Flexible Short Pulse mode
Flexible Long Pulse mode
Low pulse energy, long pulse duration and high frequency provides fine and fast dusting capabilities that disintegrate particles in 125 μm and smaller.1
High pulse energy, short pulse duration and low frequency for breaking larger or hard stones.
High pulse energy, long pulse duration and low frequency for breaking larger or hard stones.
Scientifically proven to provide up to 55% reduced retropulsion*2 during fragmentation. The Dornier
Captive mode was developed to decrease the stone
movement during application – potentially reducing
correlating lithotripsy time.
* compared to Ho:YAG
High pulse energy, short pulse duration and high frequency. Thulio’s RealPulse® technology enables anatomical endoscopic enucleation of the prostate.
Long pulse duration and a variety of different pulse energies and frequencies. Achieves highest ranked coagulation performance**3 thanks to Tm:YAG specific water absorption.
** compared to Ho:YAG and TFL
Offers a full range of available settings with short pulses.
Offers a full range of available settings with long pulses.
1
Interact with easy-to-navigate interface supported by the large rotatable touchscreen
Toggle between pre-selected settings effortlessly with dual footswitch and splitscreen function
2
Offer 100 W with the smallest footprint
Engineered lightweight and easy to move, with a standard wall plug
3
Switch seamlessly from one pre-defined mode to another
Adjust parameter settings easily with the footswitch
RealPulse Technology is what truly distinguishes Thulio from all other lasers today, featuring:
Use of optimally aligned diodes deliver highly efficient energy conversion
A patented method improves laser stability and output efficiency
Use of Thulium:YAG crystal
Developed in-house with our industry-established German engineering, the Thulio delivers a pulsed laser performance so transformative, it must be experienced firsthand.
Laser type
Thulium (Tm:YAG) pulsed solid state
Wavelength
2013 nm
Output (max.)
100 W
Peak power (max.)
3.7 kW
Frequency
5-300 Hz
Application modes
Dusting, Captive Fragmenting, Standard Fragmenting, Enucleation, Soft Tissue (Coagulation), Flexible Short Pulse, Flexible Long Pulse
Weight
97 kg (laser device)
105 kg (including safe working load)
Dimensions
Including monitor:
(W) 42 x (D) 62 x (H) 139 cm
Excluding monitor:
(W) 42 x (D) 62 x (H) 112 cm
Noise emission (max.)
65 dB
Order Number | Description | Colour Coding | Core Diameter | No. of Sterile Pieces per Packaging |
|---|---|---|---|---|
K2016360* | 200 µm Single Use Thulio Laser Fiber | Blue | 200 µm | 3 pcs |
K2016361 | 270 µm Slim Single Use Thulio Laser Fiber | White | 272 µm | 3 pcs |
K2016363 | 400 µm Single Use Thulio Laser Fiber | Yellow | 365 µm | 3 pcs |
K2016365 | 600 µm Single Use Thulio Laser Fiber | Green | 550 µm | 3 pcs |
K2016366 | 1000 µm Single Use Thulio Laser Fiber | Red | 940 µm | 3 pcs |
Dornier Thulio Performance Fibers are compatible with Dornier Thulio K2016000 only.
*Only available in EU countries (European Union)
Order Number | Description | Colour Coding | Core Diameter | No. of Sterile Pieces per Packaging |
|---|---|---|---|---|
K2016370 | 270 µm, Slim, 10x Reusable Thulio Laser Fiber | White | 272 µm | 3 pcs |
K2016371 | 400 µm, 10x Reusable Thulio Laser Fiber | Yellow | 365 µm | 3 pcs |
K2016372 | 600 µm, 10x Reusable Thulio Laser Fiber | Green | 550 µm | 3 pcs |
K2016373 | 1000 µm, 10x Reusable Thulio Laser Fiber | Red | 940 µm | 3 pcs |
Reusable Dornier Thulio Performance Fibers are authorized for 10 usage cycles (usability). Steam sterilization at 132°C (270°F). For more details, please refer to the instructions for use.
Dornier Thulio Performance Fibers are compatible with Dornier Thulio K2016000 only.
REFERENCES:
1. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). In Vitro Dusting Performance of a New Solid State Thulium Laser Compared to Holmium Laser Lithotripsy. J Endourol, 35(2), 221-225. https://doi.org/10.1089/end.2020.0525
2. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol, 39(9), 3651-3656. https://doi.org/10.1007/s00345-021-03668-8
3. Yilmaz, M., Esser, J., Kraft, L. et al. Experimental ex-vivo performance study comparing a novel, pulsed thulium solid-state laser, chopped thulium fibre laser, low and high-power holmium:YAG laser for endoscopic enucleation of the prostate. World J Urol 40, 601–606 (2022). https://doi.org/10.1007/s00345-021-03825-z
| YEAR | PUBLICATION | REFERENCING |
|---|---|---|
| 2024 |
Real-world experience with the new pulsed solid-state Thulium: YAG laser (Thulio) for endoscopic enucleation of the prostatevon Bargen, MF., Glienke, M., Tonyali, S. (2024) Real-world experience with the new pulsed solid-state Thulium: YAG laser (Thulio) for endoscopic enucleation of the prostate. World Journal of Urology. 42:467.
|
von Bargen, MF., Glienke, M., Tonyali, S. (2024) Real-world experience with the new pulsed solid-state Thulium: YAG laser (Thulio) for endoscopic enucleation of the prostate. World Journal of Urology. 42:467. |
| 2023 |
Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 casesPanthier, F., Solano, C., Chicaud, M. et al. (2023) Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases. World J Urol 41, 2119–2125. https://doi.org/10.1007/s00345-023-04501-0
|
Panthier, F., Solano, C., Chicaud, M. et al. (2023) Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases. World J Urol 41, 2119–2125. https://doi.org/10.1007/s00345-023-04501-0 |
| 2023 |
Pulsed thulium:YAG laser-ready to dust all urinary stone composition types? Results from a PEARLS analysisKwok, JL., Ventimiglia, E., De Coninck, V. et al. (2023) Pulsed thulium:YAG laser—ready to dust all urinary stone composition types? Results from a PEARLS analysis. World J Urol. https://doi.org/10.1007/s00345-023-04549-y
|
Kwok, JL., Ventimiglia, E., De Coninck, V. et al. (2023) Pulsed thulium:YAG laser—ready to dust all urinary stone composition types? Results from a PEARLS analysis. World J Urol. https://doi.org/10.1007/s00345-023-04549-y |
| 2023 |
What to expect from the novel pulsed thulium:YAG laser? A systematic review of endourological applications.Ventimiglia, E., Robesti, D., Bevilacqua, L. et al. (2023) What to expect from the novel pulsed thulium:YAG laser? A systematic review of endourological applications. World J Urol. https://doi.org/10.1007/s00345-023-04580-z
|
Ventimiglia, E., Robesti, D., Bevilacqua, L. et al. (2023) What to expect from the novel pulsed thulium:YAG laser? A systematic review of endourological applications. World J Urol. https://doi.org/10.1007/s00345-023-04580-z |
©2024 Dornier MedTech. All rights reserved. The contents herein are subject to change without prior notice. Dornier Thulio®, Captive®, RealPulse® are registered trademarks of Dornier MedTech and its use throughout this website is protected. The information contained in this website is for information purposes only and provided "as is". The actual product may vary from the images shown. The product shown is only offered in countries where it may be legally offered. Please check the availability with your local sales representative or customer service.
Have a question about our products and services, or general feedback for us?
We’d love to hear from you. Fill up the form below and our customer representative will get in touch shortly.
"*" indicates required fields
©2026 Dornier MedTech. All rights reserved. The contents herein and product shown (including its design, specifications and functions) are subject to change without notice. Dornier Thulio® is a registered trademark of Dornier MedTech and its use throughout this website is protected. The information on this website is for information purposes only and provided “as is” without any warranties of any kind, whether expressed or implied, including but not limited to, implied warranties of satisfactory quality, fitness for a particular purpose and/or correctness. The actual product may vary from the images shown.
The product shown is only offered in jurisdictions where it may be legally offered. Please check availability with your local sales representative or customer service.
Submit your information below to receive the download link in your mailbox
We can’t wait to share about our products with you! Product and brochure availability may vary between countries, but we’ll be in touch.
"*" indicates required fields
Fill out the form below to receive the download link.