The product shown is only offered in jurisdictions where it may be legally offered. Please check availability with your local sales representative or customer service.
Operating at 2013 nm and delivering up to 3,700 W peak power, Thulio empowers urologists to confidently treat stones, BPH, and soft tissue applications with one versatile system that excels across all major endourological applications.
Stone
Fragmentation
Stone
Dusting
Stone
Retropulsion
Tissue
Enucleation
Tissue
Coagulation
All STRENGTH IN ONE LASER
Dornier Thulio – pulsed Tm:YAG
Highly efficient
in stone ablation1
Excellent
fine dusting comparable to TFL2
Low
retropulsion compared to Ho:YAG3
Highly efficient
smooth plane development4
Excellent
Often the best coagulation profile5
Ho:YAG
TFL
Ho:YAG
Strong
Ideal for very hard stones6
Inferior
to pulsed Tm:YAG7
High
compared to pulsed Tm:YAG7
Highly efficient
most mature laser technology4
OK5
Ho:YAG
TFL
Thulium Fiber (TFL)
Less efficient
in dense stone compositions8
Excellent
Produces fine dust particles9
Minimal9
Expanding
clinical evidence base10
Very good
hemostatic performance11
Dornier Thulio® combines effective lithriopsy, precise tissue performance, and broad clinical versatility on a single pulsed Tm:YAG platform —supported by a rapidly expanding body of prospective, comparative, multicenter, and systematic-review evidence.
Kidney Stones
Kidney Stones
High stone-free rates across procedures
(flex. URS, ECIRS & PCNL)12 reproducible results across different clinical settings.13
Effective dusting across stone compositions providing flexibility for everyday stone treatments.14
55% reduced retropulsion for enhanced control3
Supporting procedural efficiency3
16% shorter lasing time using FANS
Compared to TFL15
Proven performance for large and complex stones.13
BPH
BPH
96.1% patient satisfaction post-EEP16
Strong hemostatic control
Clinical reviews consistently report excellent coagulation characteristics, helping surgeons maintain visualization and procedural flow throughout treatment.17
Pulsed ThuLEP with Thulio delivers proven results over HoLEP16
UTUC
UTUC
80% tumor-free rate
Ablation performance on par with TFL outshining Ho:YAG18
REFERENCES:
Witness the infinite versatility of Thulio®, our 100W high-power pulsed Thulium:YAG laser, in action. Trusted by clinicians worldwide and backed by a proven track record, Thulio® offers exceptional performance and reliable care, empowering you to provide the quality treatment your patients deserve.
Filtre
Thulio offre un large éventail de modes d’application, s’adaptant à vos besoins et permettant des procédures plus fluides.
Mode Dusting (pulverisation)
Mode Fragmenting (fragmentation)
Mode Fragmenting Captive®
Mode énucléation
Mode Soft Tissue
Mode de pulsations courtes flexible
Mode de pulsations longues flexible
Une faible énergie de pulsation, une longue durée de pulsation et une fréquence élevée offrent des capacités de dusting fin et rapide qui désintègrent les particules de 125 μm et moins.1
Énergie de pulsation élevée, courte durée de pulsation et basse fréquence pour briser les calculs plus gros ou durs.
Énergie de pulsation élevée, longue durée de pulsation et basse fréquence pour briser les calculs plus gros ou durs.
Scientifiquement prouvé pour fournir jusqu’à 55 % de rétropulsion en moins*2 lors de la fragmentation. Le mode Dornier Captive® a été développé pour diminuer le mouvement des calculs pendant l’application – réduisant potentiellement le temps de lithotripsie corrélatif.
* par rapport à Ho:YAG
Énergie de pulsation élevée, courte durée de pulsation et haute fréquence.
La technologie RealPulse® de Thulio® permet l’énucléation endoscopique anatomique de la prostate.
Longue durée de pulsation et grande variété d’énergies et de fréquences de pulsation. Permet d’obtenir la meilleure performance en matière de coagulation**3 grâce à une absorption d’eau spécifique Tm:YAG
** par rapport à Ho:YAG et TFL
Offre une gamme complète de réglages disponibles avec des pulsations courtes.
Offre une gamme complète de réglages disponibles avec des pulsations longues.
1
Interact with easy-to-navigate interface supported by the large rotatable touchscreen
Toggle between pre-selected settings effortlessly with dual footswitch and splitscreen function
2
Offer 100 W with the smallest footprint
Engineered lightweight and easy to move, with a standard wall plug
3
Switch seamlessly from one pre-defined mode to another
Adjust parameter settings easily with the footswitch
La technologie RealPulse® est ce qui distingue vraiment Thulio de tous les autres lasers actuels :
L’utilisation de diodes alignées de façon optimale une conversion d’énergie très efficace
La méthode brevetée améliore la stabilité du laser et l’efficacité de sortie
Utilisation de Thulium:YAG cristal
Développé en interne avec notre ingénierie allemande reconnue, le Thulio offre une performance laser pulsée si transformatrice qu’elle doit être expérimentée de première main.
Type de laser
État solide à pulsation thulium (Tm:YAG)
Longueur d’onde
2013 nm
Puissance de sortie (max.)
100 W
Pic de puissance (max.)
3.7 kW
Fréquence de pulsation
5-300 Hz
Modes d’utilisation
Dusting, Captive Fragmenting, Standard Fragmenting, Enucleation, Soft Tissue (coagulation), courte pulsation flexible, longue pulsation flexible
Poids
97 kg (dispositif laser)
105 kg (charge maximum pratique comprise)
Dimensions
Avec écran:
(L) 42 x (H) 139x (P) 62cm
Sans écran:
(L) 42 x (H) 112 x (P) 62cm
Émissions sonores (max.)
65 dB
Numéro de commande | Description | Code couleur | Diamètre noyau | Nbr de pcs stériles par conditionnement |
|---|---|---|---|---|
K2016360* | 200 µm Fibre laser Thulio à usage unique | Bleu | 200 µm | 3 pcs |
K2016361 | 270 µm Minceur Fibre laser Thulio à usage unique | Blanc | 272 µm | 3 pcs |
K2016363 | 400 µm Fibre laser Thulio à usage unique | Jaune | 365 µm | 3 pcs |
K2016365 | 600 µm Fibre laser Thulio à usage unique | Vert | 550 µm | 3 pcs |
K2016366 | 1000 µm Fibre laser Thulio à usage unique | Rouge | 940 µm | 3 pcs |
Les fibres Thulio Performance Dornier sont compatibles avec le dispositif Dornier Thulio K2016000 uniquement.
*Disponible uniquement dans les pays européens (Union Européenne).
Numéro de commande | Description | Code couleur | Diamètre noyau | Nbr de pcs stériles par conditionnement |
|---|---|---|---|---|
K2016370 | 270 µm, Mince, 10x fibre laser Thulio réutilisable | Blanc | 272 µm | 3 pcs |
K2016371 | 400 µm, 10x fibre laser Thulio réutilisable | Jaune | 365 µm | 3 pcs |
K2016372 | 600 µm, 10x fibre laser Thulio réutilisable | Vert | 550 µm | 3 pcs |
K2016373 | 1000 µm, 10x fibre laser Thulio réutilisable | Rouge | 940 µm | 3 pcs |
Les fibres Thulio Performance Dornier réutilisables sont autorisées pour 10 cycles d’utilisation (utilisabilité). Stérilisation par vapeur à 132 °C. Pour plus de détails, reportez-vous au mode d’emploi.
Les fibres Thulio Performance Dornier sont compatibles avec le dispositif Dornier Thulio K2016000 uniquement.
RÉFÉRENCEMENT:
1. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). In Vitro Dusting Performance of a New Solid State Thulium Laser Compared to Holmium Laser Lithotripsy. J Endourol, 35(2), 221-225. https://doi.org/10.1089/end.2020.0525
2. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol, 39(9), 3651-3656. https://doi.org/10.1007/s00345-021-03668-8
3. Yilmaz, M., Esser, J., Kraft, L. et al. Experimental ex-vivo performance study comparing a novel, pulsed thulium solid-state laser, chopped thulium fibre laser, low and high-power holmium:YAG laser for endoscopic enucleation of the prostate. World J Urol 40, 601–606 (2022). https://doi.org/10.1007/s00345-021-03825-z
| Dornier Thulio® in-vivo efficiency & safety for stone lithotripsy | Dornier Thulio® offers effective and safe laser lithotripsy, fulfilling the criteria of an ideal laser. |
Download |
| Dornier Thulio®’s in-vivo efficiency & safety for EEP | Dornier Thulio® offers a safe and effective option for laser enucleation of the prostate with high postoperative patient satisfaction. |
Download |
| Dornier Thulio® dusting ablation efficiency during in vitro lithotripsy of all urinary stone composition types | Dornier Thulio®, the new pulsed-Tm:YAG laser, is capable of efficiently dusting all seven common human urinary stone compositions. |
Download |
| Initial single-center clinical experience | Dornier Thulio®, the new pulsed-Tm:YAG laser, is a safe and effective source for endocorporeal laser lithotripsy (ELL) during retrograde intrarenal surgery (RIRS). |
Download |
| ANNÉE | PUBLICATION | RÉFÉRENCEMENT |
|---|---|---|
| 2026 |
A RANDOMIZED CLINICAL TRIAL COMPARING DORNIER P-TM:YAG LASER TO TFL LASER FOR STONE DUSTING ABLATION EFFICIENCYMcDermott JT, Sheetz TJ, Berger JH, Finegan JL, Blake R, Bajakian T, Bechis SK, Monga M, Sur RL. (2026) A RANDOMIZED CLINICAL TRIAL COMPARING DORNIER P-TM:YAG LASER TO TFL LASER FOR STONE DUSTING ABLATION EFFICIENCY. J Urol 215, e488. https://doi.org/10.1097/01.JU.0001191404.60845.a4.17
|
McDermott JT, Sheetz TJ, Berger JH, Finegan JL, Blake R, Bajakian T, Bechis SK, Monga M, Sur RL. (2026) A RANDOMIZED CLINICAL TRIAL COMPARING DORNIER P-TM:YAG LASER TO TFL LASER FOR STONE DUSTING ABLATION EFFICIENCY. J Urol 215, e488. https://doi.org/10.1097/01.JU.0001191404.60845.a4.17 |
| 2026 |
Feasibility and efficiency of the use of pulsed thulium: YAG (Thulio) laser for ECIRS: a multicenter evaluationPauwaert K, Gernay G, Vercelli E, Van Bos E, Boeykens M, Slots C, Gökce Mİ, et al. (2026) Feasibility and efficiency of the use of pulsed thulium:YAG (Thulio) laser for ECIRS: a multicenter evaluation. World J Urol. https://doi.org/10.1007/s00345-026-06240-4
|
Pauwaert K, Gernay G, Vercelli E, Van Bos E, Boeykens M, Slots C, Gökce Mİ, et al. (2026) Feasibility and efficiency of the use of pulsed thulium:YAG (Thulio) laser for ECIRS: a multicenter evaluation. World J Urol. https://doi.org/10.1007/s00345-026-06240-4 |
| 2026 |
Flexible ureterorenoscopy and lithotripsy with pulsed thulium: YAG laser: a multicenter retrospective studyGonzález GC, Kwok JL, Scilipoti P, et al. (2026) Flexible ureterorenoscopy and lithotripsy with pulsed thulium:YAG laser: a multicenter retrospective study. World J Urol 44, 383. https://doi.org/10.1007/s00345-026-06467-1
|
González GC, Kwok JL, Scilipoti P, et al. (2026) Flexible ureterorenoscopy and lithotripsy with pulsed thulium:YAG laser: a multicenter retrospective study. World J Urol 44, 383. https://doi.org/10.1007/s00345-026-06467-1 |
| 2026 |
A paradigm shift in urology training: laser endoscopic enucleation of the prostate may be easier than transurethral resection of the prostate in the learning curve of urology residentsMorgan IL, da Silva GE, Nagato DC, et al. (2026) A paradigm shift in urology training: laser endoscopic enucleation of the prostate may be easier than transurethral resection of the prostate in the learning curve of urology residents. Prostate Int 14, 81–88. https://doi.org/10.1016/j.prnil.2025.12.001
|
Morgan IL, da Silva GE, Nagato DC, et al. (2026) A paradigm shift in urology training: laser endoscopic enucleation of the prostate may be easier than transurethral resection of the prostate in the learning curve of urology residents. Prostate Int 14, 81–88. https://doi.org/10.1016/j.prnil.2025.12.001 |
©2024 Dornier MedTech. Tous droits réservés. Le contenu de ce site est susceptible d'être modifié sans préavis. Dornier Thulio®, Captive®, RealPulse® sont des marques déposées de Dornier MedTech et leur utilisation sur ce site est protégée. Les informations contenues dans ce site web sont fournies à titre indicatif et "en l'état". Le produit réel peut différer des images présentées. Le produit présenté n'est offert que dans les pays où il peut être légalement offert. Veuillez vérifier la disponibilité du produit auprès de votre représentant local ou du service clientèle.
Vous avez une question sur nos produits et services, ou les commentaires généraux pour nous? Nous aimerions recevoir de vos nouvelles. Remplissez le formulaire ci-dessous et notre représentant client se contactera sous peu.
« * » indique les champs nécessaires
©2026 Dornier MedTech. All rights reserved. The contents herein and product shown (including its design, specifications and functions) are subject to change without notice. Dornier Thulio® is a registered trademark of Dornier MedTech and its use throughout this website is protected. The information on this website is for information purposes only and provided “as is” without any warranties of any kind, whether expressed or implied, including but not limited to, implied warranties of satisfactory quality, fitness for a particular purpose and/or correctness. The actual product may vary from the images shown.
The product shown is only offered in jurisdictions where it may be legally offered. Please check availability with your local sales representative or customer service.
Submit your information below to receive the download link in your mailbox
Nous avons hâte de vous faire découvrir nos produits ! La disponibilité des produits et des brochures peut varier selon les pays, mais nous prendrons contact avec vous.
« * » indique les champs nécessaires
Remplissez le formulaire ci-dessous pour recevoir le lien de téléchargement.