Une polyvalence infinie

The product shown is only offered in jurisdictions where it may be legally offered. Please check availability with your local sales representative or customer service.

Thulio Video Cover

Pulsed Thulium:YAG - Different by Design

Operating at 2013 nm and delivering up to 3,700 W peak power, Thulio empowers urologists to confidently treat stones, BPH, and soft tissue applications with one versatile system that excels across all major endourological applications.

Stone
Fragmentation

Stone
Dusting

Stone
Retropulsion

Tissue
Enucleation

Tissue
Coagulation

All STRENGTH IN ONE LASER

Dornier Thulio – pulsed Tm:YAG

Highly efficient

in stone ablation1

Excellent

fine dusting comparable to TFL2

Low

retropulsion compared to Ho:YAG3

Highly efficient

smooth plane development4

Excellent

Often the best coagulation profile5

Ho:YAG

TFL

Ho:YAG

Strong

Ideal for very hard stones6

Inferior

to pulsed Tm:YAG7

High

compared to pulsed Tm:YAG7

Highly efficient

most mature laser technology4

OK5

Ho:YAG

TFL

Thulium Fiber (TFL)

Less efficient

in dense stone compositions8

Excellent

Produces fine dust particles9

Minimal9

Expanding

clinical evidence base10

Very good

hemostatic performance11

Clinical Confidence. Procedural Versatility. Strong Evidence.

Dornier Thulio® combines effective lithriopsy, precise tissue performance, and broad clinical versatility on a single pulsed Tm:YAG platform —supported by a rapidly expanding body of prospective, comparative, multicenter, and systematic-review evidence.

Kidney Stones

Kidney Stones

High stone-free rates across procedures

(flex. URS, ECIRS & PCNL)12 reproducible results across different clinical settings.13

Effective dusting across stone compositions providing flexibility for everyday stone treatments.14

55% reduced retropulsion for enhanced control3

Supporting procedural efficiency3

16% shorter lasing time using FANS

Compared to TFL15

Proven performance for large and complex stones.13

BPH

BPH

96.1% patient satisfaction post-EEP16

Strong hemostatic control

Clinical reviews consistently report excellent coagulation characteristics, helping surgeons maintain visualization and procedural flow throughout treatment.17

Pulsed ThuLEP with Thulio delivers proven results over HoLEP16

  • 3.23 min shorter total surgery time
  • 4.36 min shorter enucleation time
  • 81.6% lower maximum pain score

UTUC

UTUC

80% tumor-free rate

Ablation performance on par with TFL outshining Ho:YAG18

REFERENCES:

  1. Robesti, D., La Rezza, S., Traxer, O., Kartalas Goumas, I., & Ventimiglia, E. (2026). All about pulsed thulium:YAG laser: a systematic review from YAU Endourology and EAU Endourology. Curr Opin Urol, 36(1), 57–65. https://doi.org/10.1097/mou.0000000000001351

  2. Kraft, L., Yilmaz, M., Petzold, R., et al. (2022)Dusting efficiency of a novel pulsed Thulium: Yttrium Aluminum Garnet laser vs a Thulium fiber laser. J Endourol, 36(2):259-265, https://doi.org/10.1089/end.2021.0441

  3. Petzold, R., Miernik, A. & Suarez-Ibarrola, R. (2021). Retropulasion force in laser lithotripsy—an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol 39(9), 3651–3656. https://doi.org/10.1007/s00345-021-03668-8

  4. Allaeys, C., Cornette, J., Lambert, E., De Naeyer, G., & Schatteman, P. (2026). Prospective single-center study comparing RealPulse(®) Thulium:YAG and Holmium:YAG laser enucleation of the prostate. World J Urol, 44(1), 80. https://doi.org/10.1007/s00345-025-06156-5

  5. Castellani, D., Fong, K. Y., Goumas, I. K., Tan, K.,Biligere, S., Yuen, S. K., Zawadzki, M., Bozzini, G., Hota, T., & Gauhar,V. (2026). Does pulse modulation technology improve endoscopic enucleation ofthe prostate? Real-world comparison of three contemporary laser platforms in447 patients. World J Urol, 44(1), 128. https:// doi.org/10.1007/s00345-026-06228-0

  6. Salvadó, J. A., Villena, J. M., Urrea, F., Marchant, P., Larrañaga, M., Cabello, J. M., & Marchetti, P. (2026). High-power holmium laser versus pulsed thulium laser for ureteroscopic lithotripsy: Results of a randomized prospective study. Cent European J Urol, 79(1), 30–35. https://doi.org/10.5173/ceju.2025.0044

  7. Petzold R, Miernik A, Suarez-Ibarrola R. In Vitro Dusting Performance of a New Solid State Thulium Laser Compared to Holmium Laser Lithotripsy. J Endourol. 2021;35:221-225

  8. Panthier F, Sierra A, Keller EX, et al. Comparison of p-Tm:YAG, TFL and Ho:YAG’s in vitro ablation rates on synthetic and human stones. BJUI Compass. 2025;6(8):e70067. DOI: 10.1002/bco2.70067

  9. Tang, X., Wu, S., Li, Z., Wang, D., Lei, C., Liu, T., Wang, X., & Li, S. (2024). Comparison of Thulium Fiber Laser versus Holmium laser in ureteroscopic lithotripsy: a Meta-analysis and systematic review. BMC Urol, 24(1), 44. https://doi.org/10.1186/s12894-024-01419-6

  10. Kallidonis P, et al. Pulsed Thulium:YAG laser for the management of urolithiasis. World J Urol. 2025;43:118.

  11. Spinos, T., Tatanis, V., Peteinaris, A., Somani, B., Kartalas Goumas, I., Liatsikos, E., & Kallidonis, P. (2024). Thulium fiber laser enucleation of the prostate: a systematic review of the current outcomes. Minerva Urol Nephrol, 76(2), 157–165. https://doi.org/10.23736/S2724-6051.24.05654-4

  12. Panthier, F., Solano, C., Chicaud, M. et al. (2023). Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases. World J Urol 41, 2119–2125. https://doi.org/10.1007/s00345-023-04501-0

  13. Proietti, S., Marchioni, M., Oo, M.M. et al. (2024). Flexible Ureteroscopic Lithotripsy with the Pulsed Thulium:Yttrium Aluminum Garnet Laser Thulio: Preliminary Results from a Prospective Study. Eur Urol Open Sci 67, 77–83. https://doi.org/10.1016/j.euros.2024.07.114

  14. Kwok, J.L., Ventimiglia, E., De Coninck, V. et al. (2023). Pulsed thulium:YAG laser—ready to dust all urinary stone composition types? Results from a PEARLS analysis. World J Urol 41, 2823–2831. https://doi.org/10.1007/s00345-023-04549-y

  15. Castellani, D., Fong, K.Y., Traxer, O. et al. (2025). Propensity Score Matched Analysis of Thulium Fiber vs Pulsed Thulium:Yttrium Aluminum Garnet Laser Lithotripsy in Flexible Ureteroscopy for Kidney Stone Disease Using a Flexible and Navigable Suction Ureteral Access Sheath: Results From a Prospective, Multicenter Study of the EAU Section of Endourology. Urology. https://doi.org/10.1016/j.urology.2025.01.065

  16. von Bargen, M.F., Glienke, M., Tonyali, S. et al. (2024). Real-world experience with the new pulsed solid-state Thulium:YAG laser (Thulio) for endoscopic enucleation of the prostate. World J Urol 42, 467. https://doi.org/10.1007/s00345-024-05141-8

  17. Yilmaz, M., Esser, J., Kraft, L. et al. (2022). Experimental ex-vivo performance study comparing a novel, pulsed thulium solid-state laser, chopped thulium fibre laser, low and high-power holmium:YAG laser for endoscopic enucleation of the prostate. World J Urol 40, 601–606. https://doi.org/10.1007/s00345-021-03825-z

  18. Proietti S, De Leonardis F, Hernandez Gaytan CA, et al. (2025). In-medio stat virtus: Exploring the potential of the pulsed thulium:YAG laser in the endoscopic management of upper urinary tract urothelial carcinoma. Cent European J Urol.; 78: 271–276 https://doi.org/10.1016/j.euf.2025.06.002


Thulio® In Action

Witness the infinite versatility of Thulio®, our 100W high-power pulsed Thulium:YAG laser, in action. Trusted by clinicians worldwide and backed by a proven track record, Thulio® offers exceptional performance and reliable care, empowering you to provide the quality treatment your patients deserve.

Filtre

These testimonials are coming soon. Check back soon for new reviews.

Polyvalent par sa conception

Thulio offre un large éventail de modes d’application, s’adaptant à vos besoins et permettant des procédures plus fluides.

Mode Dusting (pulverisation)

Mode Fragmenting (fragmentation)

Mode Fragmenting Captive®

Mode énucléation

Mode Soft Tissue

Mode de pulsations courtes flexible

Mode de pulsations longues flexible

Mode Dusting (pulverisation)

Une faible énergie de pulsation, une longue durée de pulsation et une fréquence élevée offrent des capacités de dusting fin et rapide qui désintègrent les particules de 125 μm et moins.1

Mode Fragmenting

Énergie de pulsation élevée, courte durée de pulsation et basse fréquence pour briser les calculs plus gros ou durs.

Fragmenting Mode Fr

Mode Fragmenting Captive®

Énergie de pulsation élevée, longue durée de pulsation et basse fréquence pour briser les calculs plus gros ou durs.
Scientifiquement prouvé pour fournir jusqu’à 55 % de rétropulsion en moins*2 lors de la fragmentation. Le mode Dornier Captive® a été développé pour diminuer le mouvement des calculs pendant l’application – réduisant potentiellement le temps de lithotripsie corrélatif.

Captive Fragmenting Mode Fr

* par rapport à Ho:YAG

Mode énucléation

Énergie de pulsation élevée, courte durée de pulsation et haute fréquence.
La technologie RealPulse® de Thulio® permet l’énucléation endoscopique anatomique de la prostate.

Enucleation Mode Fr

Mode Soft Tissue

Longue durée de pulsation et grande variété d’énergies et de fréquences de pulsation. Permet d’obtenir la meilleure performance en matière de coagulation**3 grâce à une absorption d’eau spécifique Tm:YAG

Soft Tissue Mode Fr

** par rapport à Ho:YAG et TFL

Mode de pulsations courtes flexible

Offre une gamme complète de réglages disponibles avec des pulsations courtes.

Flexible Short Pulse Mode Fr

Mode de pulsations longues flexible

Offre une gamme complète de réglages disponibles avec des pulsations longues.

Flexible Long Pulse Mode Fr

Notre laser de 100 W le plus compact

Asset 9
5@2x

Écran ergonomique et instinctif

Laser compact et
puissant

  • Compact
    (42 x 62 cm)
  • Funzionamento silenzioso
    (max. 65 dB)
  • Prise de
    courant standard

Pédale double sans fil connectée

1

Écran ergonomique et instinctif

Interact with easy-to-navigate interface supported by the large rotatable touchscreen

Toggle between pre-selected settings effortlessly with dual footswitch and splitscreen function

2

Laser compact et puissant

Offer 100 W with the smallest footprint

Engineered lightweight and easy to move, with a standard wall plug

3

Pédale double sans fil connectée

Switch seamlessly from one pre-defined mode to another

Adjust parameter settings easily with the footswitch

Technologie RealPulse® - Augmente les performances du Thulio

La technologie RealPulse® est ce qui distingue vraiment Thulio de tous les autres lasers actuels :

L’utilisation de diodes alignées de façon optimale une conversion d’énergie très efficace

La méthode brevetée améliore la stabilité du laser et l’efficacité de sortie

Utilisation de Thulium:YAG cristal

Développé en interne avec notre ingénierie allemande reconnue, le Thulio offre une performance laser pulsée si transformatrice qu’elle doit être expérimentée de première main.

Données techniques

Type de laser

État solide à pulsation thulium (Tm:YAG)

Longueur d’onde

2013 nm

Puissance de sortie (max.)

100 W

Pic de puissance (max.)

3.7 kW

Fréquence de pulsation

5-300 Hz

Modes d’utilisation

Dusting, Captive Fragmenting, Standard Fragmenting, Enucleation, Soft Tissue (coagulation), courte pulsation flexible, longue pulsation flexible

Poids

97 kg (dispositif laser)
105 kg (charge maximum pratique comprise)

Dimensions

Avec écran:
(L) 42 x (H) 139x (P) 62cm

Sans écran:
(L) 42 x (H) 112 x (P) 62cm

Émissions sonores (max.)

65 dB

Les fibres Dornier Thulio® Performance

Numéro de commande
Description
Code couleur
Diamètre noyau
Nbr de pcs stériles par conditionnement
K2016360*
200 µm Fibre laser Thulio à usage unique
Bleu
200 µm
3 pcs
K2016361
270 µm Minceur Fibre laser Thulio à usage unique
Blanc
272 µm
3 pcs
K2016363
400 µm Fibre laser Thulio à usage unique
Jaune
365 µm
3 pcs
K2016365
600 µm Fibre laser Thulio à usage unique
Vert
550 µm
3 pcs
K2016366
1000 µm Fibre laser Thulio à usage unique
Rouge
940 µm
3 pcs

Les fibres Thulio Performance Dornier sont compatibles avec le dispositif Dornier Thulio K2016000 uniquement.

*Disponible uniquement dans les pays européens (Union Européenne).

Numéro de commande
Description
Code couleur
Diamètre noyau
Nbr de pcs stériles par conditionnement
K2016370
270 µm, Mince, 10x fibre laser Thulio réutilisable
Blanc
272 µm
3 pcs
K2016371
400 µm, 10x fibre laser Thulio réutilisable
Jaune
365 µm
3 pcs
K2016372
600 µm, 10x fibre laser Thulio réutilisable
Vert
550 µm
3 pcs
K2016373
1000 µm, 10x fibre laser Thulio réutilisable
Rouge
940 µm
3 pcs

Les fibres Thulio Performance Dornier réutilisables sont autorisées pour 10 cycles d’utilisation (utilisabilité). Stérilisation par vapeur à 132 °C. Pour plus de détails, reportez-vous au mode d’emploi.

Les fibres Thulio Performance Dornier sont compatibles avec le dispositif Dornier Thulio K2016000 uniquement.

RÉFÉRENCEMENT:

1. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). In Vitro Dusting Performance of a New Solid State Thulium Laser Compared to Holmium Laser Lithotripsy. J Endourol, 35(2), 221-225. https://doi.org/10.1089/end.2020.0525

2. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol, 39(9), 3651-3656. https://doi.org/10.1007/s00345-021-03668-8

3. Yilmaz, M., Esser, J., Kraft, L. et al. Experimental ex-vivo performance study comparing a novel, pulsed thulium solid-state laser, chopped thulium fibre laser, low and high-power holmium:YAG laser for endoscopic enucleation of the prostate. World J Urol 40, 601–606 (2022). https://doi.org/10.1007/s00345-021-03825-z

Expérience clinique

Dornier Thulio® in-vivo efficiency & safety for stone lithotripsy

Dornier Thulio® offers effective and safe laser lithotripsy, fulfilling the criteria of an ideal laser.

Download
Dornier Thulio®’s in-vivo efficiency & safety for EEP

Dornier Thulio® offers a safe and effective option for laser enucleation of the prostate with high postoperative patient satisfaction.

Download
Dornier Thulio® dusting ablation efficiency during in vitro lithotripsy of all urinary stone composition types

Dornier Thulio®, the new pulsed-Tm:YAG laser, is capable of efficiently dusting all seven common human urinary stone compositions.

Download
Initial single-center clinical experience

Dornier Thulio®, the new pulsed-Tm:YAG laser, is a safe and effective source for endocorporeal laser lithotripsy (ELL) during retrograde intrarenal surgery (RIRS).

Download

Publications

ANNÉE PUBLICATION RÉFÉRENCEMENT
2026

A RANDOMIZED CLINICAL TRIAL COMPARING DORNIER P-TM:YAG LASER TO TFL LASER FOR STONE DUSTING ABLATION EFFICIENCY

McDermott JT, Sheetz TJ, Berger JH, Finegan JL, Blake R, Bajakian T, Bechis SK, Monga M, Sur RL. (2026) A RANDOMIZED CLINICAL TRIAL COMPARING DORNIER P-TM:YAG LASER TO TFL LASER FOR STONE DUSTING ABLATION EFFICIENCY. J Urol 215, e488. https://doi.org/10.1097/01.JU.0001191404.60845.a4.17
McDermott JT, Sheetz TJ, Berger JH, Finegan JL, Blake R, Bajakian T, Bechis SK, Monga M, Sur RL. (2026) A RANDOMIZED CLINICAL TRIAL COMPARING DORNIER P-TM:YAG LASER TO TFL LASER FOR STONE DUSTING ABLATION EFFICIENCY. J Urol 215, e488. https://doi.org/10.1097/01.JU.0001191404.60845.a4.17
2026

Feasibility and efficiency of the use of pulsed thulium: YAG (Thulio) laser for ECIRS: a multicenter evaluation

Pauwaert K, Gernay G, Vercelli E, Van Bos E, Boeykens M, Slots C, Gökce Mİ, et al. (2026) Feasibility and efficiency of the use of pulsed thulium:YAG (Thulio) laser for ECIRS: a multicenter evaluation. World J Urol. https://doi.org/10.1007/s00345-026-06240-4
Pauwaert K, Gernay G, Vercelli E, Van Bos E, Boeykens M, Slots C, Gökce Mİ, et al. (2026) Feasibility and efficiency of the use of pulsed thulium:YAG (Thulio) laser for ECIRS: a multicenter evaluation. World J Urol. https://doi.org/10.1007/s00345-026-06240-4
2026

Flexible ureterorenoscopy and lithotripsy with pulsed thulium: YAG laser: a multicenter retrospective study

González GC, Kwok JL, Scilipoti P, et al. (2026) Flexible ureterorenoscopy and lithotripsy with pulsed thulium:YAG laser: a multicenter retrospective study. World J Urol 44, 383. https://doi.org/10.1007/s00345-026-06467-1
González GC, Kwok JL, Scilipoti P, et al. (2026) Flexible ureterorenoscopy and lithotripsy with pulsed thulium:YAG laser: a multicenter retrospective study. World J Urol 44, 383. https://doi.org/10.1007/s00345-026-06467-1
2026

A paradigm shift in urology training: laser endoscopic enucleation of the prostate may be easier than transurethral resection of the prostate in the learning curve of urology residents

Morgan IL, da Silva GE, Nagato DC, et al. (2026) A paradigm shift in urology training: laser endoscopic enucleation of the prostate may be easier than transurethral resection of the prostate in the learning curve of urology residents. Prostate Int 14, 81–88. https://doi.org/10.1016/j.prnil.2025.12.001
Morgan IL, da Silva GE, Nagato DC, et al. (2026) A paradigm shift in urology training: laser endoscopic enucleation of the prostate may be easier than transurethral resection of the prostate in the learning curve of urology residents. Prostate Int 14, 81–88. https://doi.org/10.1016/j.prnil.2025.12.001

©2024 Dornier MedTech. Tous droits réservés. Le contenu de ce site est susceptible d'être modifié sans préavis. Dornier Thulio®, Captive®, RealPulse® sont des marques déposées de Dornier MedTech et leur utilisation sur ce site est protégée. Les informations contenues dans ce site web sont fournies à titre indicatif et "en l'état". Le produit réel peut différer des images présentées. Le produit présenté n'est offert que dans les pays où il peut être légalement offert. Veuillez vérifier la disponibilité du produit auprès de votre représentant local ou du service clientèle.

Nous sommes là pour vous aider.

Vous avez une question sur nos produits et services, ou les commentaires généraux pour nous? Nous aimerions recevoir de vos nouvelles. Remplissez le formulaire ci-dessous et notre représentant client se contactera sous peu.

©2026 Dornier MedTech. All rights reserved. The contents herein and product shown (including its design, specifications and functions) are subject to change without notice. Dornier Thulio® is a registered trademark of Dornier MedTech and its use throughout this website is protected. The information on this website is for information purposes only and provided “as is” without any warranties of any kind, whether expressed or implied, including but not limited to, implied warranties of satisfactory quality, fitness for a particular purpose and/or correctness. The actual product may vary from the images shown.

The product shown is only offered in jurisdictions where it may be legally offered. Please check availability with your local sales representative or customer service.

Please select your preferred language

Americas

Download your clinical insights

Submit your information below to receive the download link in your mailbox

Demander une brochure produit

Nous avons hâte de vous faire découvrir nos produits ! La disponibilité des produits et des brochures peut varier selon les pays, mais nous prendrons contact avec vous.

Téléchargez notre brochure patients.

Remplissez le formulaire ci-dessous pour recevoir le lien de téléchargement.