WEBINAR: Incise. Control. Enucleate. with Dr. Ali Antar

WEBINAR

Achieve More with Thulio®

Thulio’s pulsed Thulium:YAG technology delivers a single, versatile laser optimized for all major endo‑urology procedures—ensuring urologists always have the right tool to deliver high‑quality patient care.

Thulio: Excellence without Compromise

Thulio pairs pulsed Thulium:YAG performance with practice‑focused design—delivering Ho:YAG‑like fragmentation1 and enucleation2 with TFL‑comparable dusting3 in a single laser for stone and BPH treatments.

Thulio® machine - Thulium:YAG urologist laser
Image
Incredible possibility…
Delivers a 95% stone-free rate4
16% shorter lasing time using FANS*5
Reduces retropulsion by up to 55% percent6
3,700 watts of maximum peak power enables powerful fragmentation and anatomical enucleation1,2
Highest enucleation efficiency** and significant improvement of hemostatic control6,7
Offers very high - 96.1% - patient satisfaction2

*compared to TFL

**compared to Ho:YAG

...in a convenient package
Runs on a standard power outlet
60% less floor space than Ho:YAG9
50% quieter than Ho:YAG9
Thoughtfully designed ergonomics
Praised by practitioners for its ease of use10
Thulio was designed to adapt to the needs of today’s urologist, enabling smooth, reliable procedures.

Thulio was designed to adapt to the needs of today’s urologist, enabling smooth, reliable procedures.

Experience Thulio Webinars

Hear first-hand how Thulio is transforming urology practices today.

Incise. Control.
Enucleate.

Dr. Ali Antar
April 29, 2026

Enucleate. Fragment. Finish: Powered by Thulio.

Dr. Tim Large
January 21, 2026

Dust. Suction. Done: Thulio’s Edge in Stone Surgery

Dr. Seth Bechis
October 15, 2025

Upcoming Events

Connect with our team and experience Thulio firsthand.

May 15 - 18, 2026

AUA Annual Meeting 2026

Washington, DC

Discover the Thulio Difference

Find out why Thulio is trusted by today’s leading practitioners to deliver confidence and consistency for stone and BPH procedures.

REFERENCES:

1. Kraft, L., Petzold, R., Suarez-Ibarrola, R. et al. (2022). In vitro fragmentation performance of a novel, pulsed Thulium slid-state laser compared to a Thulium fibre laser and standard Ho:YAG laser. Lasers Med Sci 37, 2071–2078 https://doi.org/10.1007/s10103-021-03495-8

2. von Bargen, M.F., Glienke, M., Tonyali, S. et al. (2024). Real-world experience with the new pulsed solid-state Thulium: YAG laser (Thulio) for endoscopic enucleation of the prostate. World J Urol 42, 467. https://doi.org/10.1007/s00345-024-05141-8

3. Kraft, L., Yilmaz, M., Petzold, R., et al. (2022). Dusting efficiency of a novel, pulsed Thulium: YAG laser versus a Thulium fiber laser, J Endourol., 36(2):259-265. https://doi.org/10.1089/end.2021.0441

4. Panthier F, Solano C, Chicaud M, Kutchukian S, Candela L, Doizi S, Corrales M, Traxer O. Initial clinical experience with the pulsed solid-state thulium YAG laser from Dornier during RIRS: first 25 cases. World J Urol. 2023 Aug;41(8):2119-2125. doi: 10.1007/s00345-023-04501-0. Epub 2023 Jul 6. PMID: 37414942.

5. Castellani, D., Fong, K.Y., Traxer, O. et al (2025). Propensity Score Matched Analysis of Thulium Fiber vs Pulsed Thulium:Yttrium Aluminum Garnet Laser Lithotripsy in Flexible Ureteroscopy for Kidney Stone Disease Using a Flexible and Navigable Suction Ureteral Access Sheath: Results From a Prospective, Multicenter Study of the EAU Section of Endourology. https://doi.org/10.1016/j.urology.2025.01.065

6. Petzold, R., Miernik, A. & Suarez-Ibarrola, R. (2021). Retropulsion force in laser lithotripsy—an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol 39(9), 3651–3656. https://doi.org/10.1007/s00345-021-03668-8

7. Castellani D, Fong KY, Goumas IK, et al. Does pulse modulation technology improve endoscopic enucleation of the prostate? Real-world comparison of three contemporary laser platforms in 447 patients. World J Urol. 2026;44(1):128. Published 2026 Jan 25. doi:10.1007/s00345-026-06228-0

8. Glienke M, von Bargen MF, Özkan A, et al. Evaluation of the Transition from Holmium:YAG to Pulsed Thulium:YAG for Laser Endoscopic Enucleation of the Prostate and the Effect on Procedural Performance. Eur Urol Open Sci. 2026;85:111-117. Published 2026 Feb 13. doi:10.1016/j.euros.2026.01.010

9. Data on file @ Dornier MedTech

10. Proietti S, Marchioni M, Oo MM, Scalia R, Gisone S, Monroy RE, Schips L, Gaboardi F, Giusti G. Flexible Ureteroscopic Lithotripsy with the Pulsed Thulium:Yttrium Aluminum Garnet Laser Thulio: Preliminary Results from a Prospective Study. Eur Urol Open Sci. 2024 Aug 15;67:77-83. doi: 10.1016/j.euros.2024.07.114. PMID: 39286758;

Thulio® In Action

Witness the infinite versatility of Thulio®, our 100W high-power pulsed Thulium:YAG laser, in action. Trusted by clinicians worldwide and backed by a proven track record, Thulio® offers exceptional performance and reliable care, empowering you to provide the quality treatment your patients deserve.

Filter

These testimonials are coming soon. Check back soon for new reviews.

Versatile By Design

Thulio offers a wide range of application modes, adapting to your needs and enabling smoother procedures.

1 Edited
3@2x.png

Dusting mode

31@2x.png

Fragmenting mode

Whatsapp Image 2024 09 02 At 3.49fix.png

Captive Fragmenting mode

Enucleation Icon.png

Enucleation mode

35@2x.png

Soft Tissue mode

36 1@2x.png

Flexible Short Pulse mode

38@2x.png

Flexible Long Pulse mode

Dusting mode

Low pulse energy, long pulse duration and high frequency provides fine and fast dusting capabilities that disintegrate particles in 125 μm and smaller.1

Dusting@2x.png

Fragmenting mode

High pulse energy, short pulse duration and low frequency for breaking larger or hard stones.

Fragmenting@2x.png

Captive® Fragmenting mode

High pulse energy, long pulse duration and low frequency for breaking larger or hard stones.
Scientifically proven to provide up to 55% reduced retropulsion*2 during fragmentation. The Dornier
Captive mode was developed to decrease the stone
movement during application – potentially reducing
correlating lithotripsy time.

Captive@2x.png

* compared to Ho:YAG

Enucleation mode

High pulse energy, short pulse duration and high frequency. Thulio’s RealPulse® technology enables anatomical endoscopic enucleation of the prostate.

Enucleation@2x.png

Soft Tissue mode

Long pulse duration and a variety of different pulse energies and frequencies. Achieves highest ranked coagulation performance**3 thanks to Tm:YAG specific water absorption.

Soft Tissue 1@2x.png

** compared to Ho:YAG and TFL

Flexible Short Pulse mode

Offers a full range of available settings with short pulses.

Flexible@2x.png

Flexible Long Pulse mode

Offers a full range of available settings with Long pulses.

Flexible Long@2x.png

Our Most Compact 100 W Laser

Asset 9.png
5@2x.png

Ergonomic and user-friendly display

Powerful and
compact laser

  • Small footprint
    (42 x 62 cm)
  • Quiet operation (max. 65 dB)
  • Standard power outlet

Smart, dual footswitch

1

Ergonomic and user-friendly display

Interact with easy-to-navigate interface supported by the large rotatable touchscreen

Toggle between pre-selected settings effortlessly with dual footswitch and splitscreen function

2

Powerful and compact laser

Offer 100 W with the smallest footprint

Engineered lightweight and easy to move, with a standard wall plug

3

Smart, dual footswitch

Switch seamlessly from one pre-defined mode to another

Adjust parameter settings easily with the footswitch

RealPulse® Technology - Supercharging Thulio's Performance

Realpulse Tech@2x E1723785312949.png

RealPulse Technology is what truly distinguishes Thulio from all other lasers today, featuring:

Asset 4 1.svg

Use of optimally aligned diodes deliver highly efficient energy conversion

A patented method improves laser stability and output efficiency

Use of Thulium:YAG crystal

Developed in-house with our industry-established German engineering, the Thulio delivers a pulsed laser performance so transformative, it must be experienced firsthand.

Technical Specifications

Laser type

Thulium (Tm:YAG) pulsed solid state

Wavelength

2013 nm

Output (max.)

100 W

Peak power (max.)

3.7 kW

Frequency

5-300 Hz

Application modes

Dusting, Captive Fragmenting, Standard Fragmenting, Enucleation, Soft Tissue (Coagulation), Flex. Short Pulse, Flex. Long Pulse

Weight

97 kg (laser device)
105 kg (including safe working load)

Dimensions

Including monitor:
(W) 42 x (D) 62 x (H) 139 cm

Excluding monitor:
(W) 42 x (D) 62 x (H) 112 cm

Noise emission (max.)

65 dB

Dornier Thulio® Performance Fibers

Order Number
Description
Colour Coding
Core Diameter
No. of Sterile Pieces
per Packaging
K2016360*
200 µm Single Use Thulio Laser Fiber
Blue
200 µm
3 pcs
K2016361
270 µm Slim Single Use Thulio Laser Fiber
White
272 µm
3 pcs
K2016363
400 µm Single Use Thulio Laser Fiber
Yellow
365 µm
3 pcs
K2016365
600 µm Single Use Thulio Laser Fiber
Green
550 µm
3 pcs
K2016366
1000 µm Single Use Thulio Laser Fiber
Red
940 µm
3 pcs

Dornier Thulio Performance Fibers are compatible with Dornier Thulio K2016000 only.

*Only available in EU countries (European Union)

REFERENCES:

1. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). In Vitro Dusting Performance of a New Solid State Thulium Laser Compared to Holmium Laser Lithotripsy. J Endourol, 35(2), 221-225. https://doi.org/10.1089/end.2020.0525

2. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol, 39(9), 3651-3656. https://doi.org/10.1007/s00345-021-03668-8

3. Yilmaz, M., Esser, J., Kraft, L. et al. Experimental ex-vivo performance study comparing a novel, pulsed thulium solid-state laser, chopped thulium fibre laser, low and high-power holmium:YAG laser for endoscopic enucleation of the prostate. World J Urol 40, 601–606 (2022). https://doi.org/10.1007/s00345-021-03825-z

Clinical Insights

Insight into the Thulio User Experience

Across 109 tracked stone and BPH cases, physicians were highly satisfied with Thulio’s performance and capabilities.

Download
p-Tm:YAG systems rated the best for coagulation

p-Tm:YAG exhibits higher coagulation performance and better fragmentation efficiency.

Download
Advantages of p-Tm:YAG over Ho:YAG technology

p-Tm:YAG offers better fragmentation, lower retropulsion and less tissue damage.

Download

Publications

YEAR PUBLICATION REFERENCING
2025

Pulsed Thulium: YAG laser for the management of Urolothiasis: a systematic review from the EAU section of endourology

Kallidonis, P., Spinos, T., Guven, S., et. al. (2025) Pulsed Thulium: YAG laser for the management of Urolothiasis: a systematic review from the EAU section of endourology. World Journal of Urology, 43:118, https://doi.org/10.1007/s00345-025-05486-8
Kallidonis, P., Spinos, T., Guven, S., et. al. (2025) Pulsed Thulium: YAG laser for the management of Urolothiasis: a systematic review from the EAU section of endourology. World Journal of Urology, 43:118, https://doi.org/10.1007/s00345-025-05486-8
2024

Thulium fiber laser versus pulsed Thulium:YAG for laser lithotripsy during flexible ureteroscopy

Panthier, F. , Solano, C., Chicaud, M. et al. (2024) Thulium fiber laser versus pulsed Thulium:YAG for laser lithotripsy during flexible ureteroscopy. Lasers in Medical Science, 39:294, https://doi.org/10.1007/s10103-024-04267-w
Panthier, F. , Solano, C., Chicaud, M. et al. (2024) Thulium fiber laser versus pulsed Thulium:YAG for laser lithotripsy during flexible ureteroscopy. Lasers in Medical Science, 39:294, https://doi.org/10.1007/s10103-024-04267-w
2025

Multivariable regression analysis of perioperative parameters for a novel pulsed solid-state Thulium: YAG laser with high peak power versus Holmium: YAG laser in prostate enucleation

Von Bargen, MF., Glienke, M., Tonyali, S., et al. (2025). Multivariable regression analysis of perioperative parameters for a novel pulsed solid-state Thulium: YAG laser with high peak power versus Holmium: YAG laser in prostate enucleation. World J Urol. https://doi.org/10.1007/s00345-025-05756-5
Von Bargen, MF., Glienke, M., Tonyali, S., et al. (2025). Multivariable regression analysis of perioperative parameters for a novel pulsed solid-state Thulium: YAG laser with high peak power versus Holmium: YAG laser in prostate enucleation. World J Urol. https://doi.org/10.1007/s00345-025-05756-5
2024

Assessment of Holmium:YAG, Pulsed-Thulium:YAG and Thulium Fiber Lasers for Urinary Stone Ablation. In Vitro Study

Sierra Del Rio, A., Panthier, F., Castillo, E., et al. (2024) Assessment of Holmium:YAG, pulsed-Thulium:YAG and Thulium Fiber Lasers for Urinary Stone Ablation. In vitro study. J Endourol. https://doi.org/10.1089/end.2024.0349
Sierra Del Rio, A., Panthier, F., Castillo, E., et al. (2024) Assessment of Holmium:YAG, pulsed-Thulium:YAG and Thulium Fiber Lasers for Urinary Stone Ablation. In vitro study. J Endourol. https://doi.org/10.1089/end.2024.0349

©2024 Dornier MedTech. All rights reserved. The contents herein are subject to change without prior notice. Dornier Thulio®, Captive®, RealPulse® are registered trademarks of Dornier MedTech and its use throughout this website is protected. The information contained in this website is for information purposes only and provided "as is". The actual product may vary from the images shown. The product shown is only offered in countries where it may be legally offered. Please check the availability with your local sales representative or customer service.

Please select your preferred language

Americas

Contact a Rep

Have a question about Thulio®? Fill out the form and we’ll get in contact shortly. Outside of the United States? Click here

Webinar Registration

Register today to discover how Thulio gives surgeons an edge in stone surgery and reshapes everyday practice in urology. Not in the United States? Register here

Incise. Control. Enucleate.

April 29, 2026
2:30 PM CDT

Download your clinical insights

Submit your information below to receive the download link in your mailbox

Thank You for Registering!

We look forward to showing you how Thulio is reshaping urology during our next webinar:

Incise. Control. Enucleate.

April 29, 2026

2:30 PM CDT

Add a reminder to your calendar

Contact Us

Contact us today to find out more

Request a Product Brochure

We can’t wait to share about our products with you! Product and brochure availability may vary between countries, but we’ll be in touch.

Download our patient brochure.

Fill out the form below to receive the download link.