Laser active
gain medium
Wavelength
Power
(max.) [W]
Peak power (max.) [W]
Schematic pulse shape
Thulium doped YAG crystal (Yttrium-Aluminium-Garnet)
λ = 2013 nm
100
3,700
Thulium doped
silica fiber
λ = 1940 nm
602
5002
Holmium doped YAG crystal (Yttrium-Aluminium-Garnet)
λ = 2100 nm
20 - 1502
1,800 - 14,5002
Schematic illustrations of laser cavities.
Illustrations adopted from Traxer, O., Keller, E.X. Thulium fiber laser: the new player for kidney stone treatment? A comparison with Holmium:YAG laser. World J Urol 38, 1883–1894 (2020). https://doi.org/10.1007/s00345-019-02654-5.
Thulio®
Thulium:YAG laser with RealPulse® technology
Laser active gain medium
Thulium doped
YAG crystal
(Yttrium-Aluminium -Garnet)
Wavelength
λ = 2013 nm
Power (max.) [W]
100
Peak power (max.) [W]
3,700
Schematic pulse shape
Thulium
Fiber Laser
Laser active gain medium
Thulium doped
silica fiber
Wavelength
λ = 1940 nm
Power (max.) [W]
602
Peak power (max.) [W]
5002
Schematic pulse shape
Ho:YAG Laser
Laser active gain medium
Holmium doped YAG crystal (Yttrium-Aluminium-Garnet)
Wavelength
λ = 1940 nm
Power (max.) [W]
20 - 1502
Peak power (max.) [W]
1,800 - 14,5002
Schematic pulse shape
Schematic illustrations of laser cavities.
Illustrations adopted from Traxer, O., Keller, E.X. Thulium fiber laser: the new player for kidney stone treatment? A comparison with Holmium:YAG laser. World J Urol 38, 1883–1894 (2020). https://doi.org/10.1007/s00345-019-02654-5.
* Holmium:YAG & Thulium Fiber Laser
1. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). Retropulsion force in laser lithotripsy-an in vitro study comparing a Holmium device to a novel pulsed solid-state Thulium laser. World J Urol, 39(9), 3651-3656. https://doi.org/10.1007/s00345-021-03668-8
2. Ventimiglia E, Robesti D, Bevilacqua L, et al. What to expect from the novel pulsed thulium:YAG laser? A systematic review of endourological applications [published online ahead of print, 2023 Sep 8]. World J Urol. 2023; https://doi.org/10.1007/s00345-023-04580-z
3. Data on file at Dornier MedTech
4. Petzold, R., Miernik, A., & Suarez-Ibarrola, R. (2021). In Vitro Dusting Performance of a New Solid State Thulium Laser Compared to Holmium Laser Lithotripsy. J Endourol, 35(2), 221-225. https://doi.org/10.1089/end.2020.0525
5. Yilmaz, M., Esser, J., Kraft, L. et al. Experimental ex-vivo performance study comparing a novel, pulsed thulium solid-state laser, chopped thulium fibre laser, low and high-power holmium:YAG laser for endoscopic enucleation of the prostate. World J Urol 40, 601–606 (2022). https://doi.org/10.1007/s00345-021-03825-z
"*" señala los campos obligatorios
©2023 Dornier MedTech. All rights reserved. The contents herein and product shown (including its design, specifications and functions) are subject to change without prior notice. Dornier Thulio®, Captive®, RealPulse® are registered trademarks of Dornier MedTech and its use throughout this document is protected. The information on this website is for information purposes only and provided “as is” without any warranties of any kind, whether expressed or implied, including but not limited to, implied warranties of satisfactory quality, fitness for a particular purpose and/or correctness. The actual product may vary from the images shown.
The product shown is only offered in jurisdictions where it may be legally offered. Please check availability with your local sales representative or customer service.
¡Estamos deseando compartir información sobre nuestros productos con usted! La disponibilidad de los productos y el folleto puede variar de un país a otro, pero nos pondremos en contacto con usted.
"*" señala los campos obligatorios
Complete el siguiente formulario para recibir el enlace de descarga.